XO 1.75 B1 ECOs

From OLPC
Revision as of 07:33, 18 July 2011 by Wad (talk | contribs)
Jump to navigation Jump to search
  This page is monitored by the OLPC team.

These are recommended engineering change orders (ECOs) to the B1 prototype of the XO-1.75 laptop. This is NOT a list of changes from B1 to C1, that is located elsewhere.

Fix MPPT

This extends the range of input voltages which the MPPT algorithm can use.

  • Change PR234 to 150K
  • Change PR235 to 220K

This was done to most B1 units, with the exception of twenty-six or so. wad has the serial numbers of laptops missing this ECO.

Increase Bulk Decoupling

This fixes a problem seen on some boards where trying to turn it on results in two fast blink of the red battery LED, cycling indefinitely. The problem is due to the +3.3V power supply shutting down when loads are added suddenly.

  • Populate PC54 w. a 22 uF, 6.3V cap (or higher). This should be a ceramic cap.

This has already been done to around a dozen motherboards, as needed for reliable booting.