Plug packs: Difference between revisions
Tonyforster (talk | contribs) |
Tonyforster (talk | contribs) |
||
Line 10: | Line 10: | ||
[[File:Chargerwaveform4.jpg]] |
[[File:Chargerwaveform4.jpg]] |
||
as above but run on battery power to 80% then |
as above but run on battery power down to 80% charge then plugged in |
||
Line 25: | Line 25: | ||
[[File:Pcwaveform.jpg]] |
[[File:Pcwaveform.jpg]] |
||
For comparison a PC power supply. Vertical scale is 0.4A/square |
For comparison a PC power supply. Vertical scale is 0.4A/square, the waveform has a wider pulse and could be expected to be less stressful on generators and transformers but not much better. |
||
==Harmonics== |
==Harmonics== |
Revision as of 21:58, 4 December 2010
Waveforms
Charger input waveforms, 0.2A/square, screen edges and centre are the input voltage zero crossings
Green wallwart AD5953 ALF, XO1.5 running 93% charge 240V input
as above but run on battery power down to 80% charge then plugged in
Green wallwart Delta ADP17FBA, XO1.5 running 93% charge 240V input
White wallwart Bestek NA0241WAA, XO1.5 running 93% charge 240V input
For comparison a PC power supply. Vertical scale is 0.4A/square, the waveform has a wider pulse and could be expected to be less stressful on generators and transformers but not much better.
Harmonics
The load is well balanced with respect to leading/lagging power factor, showing only a slight leading or capacitive power factor. The waveform is very rich in harmonics. This could lead to overheating in transformers and generators due to eddy currents.
A harmonic analysis on the following approximation of the waveform
yielded this result