This page contains safety and RF emission test reports and certifications for the [[XO-4|XO-4 Laptop]].
This page contains safety and RF emission test reports and certifications for the [[XO-4|XO-4 Laptop]].


=Safety Test Reports=
=Safety=
The [[XO-4|XO-4 Laptop]] has the following Safety certifications:
The [[XO-4|XO-4 Laptop]] comes in four variants: the XO-4, the XO-4 HS (a non-membrane keyboard), the XO-4 Touch, and the XO-4 HS Touch.
These have the following Safety certifications:


*[[Media:XO-4_ULReport.pdf |UL cert for XO-4]]
*[[Media:XO-4_ULReport.pdf |UL cert for XO-4/XO-4 Touch]]
*[[Media:XO-4HS_ULReport.pdf |UL cert for XO-4 HS]]
*[[Media:XO-4HS_ULReport.pdf |UL cert for XO-4 HS/XO-4 HS Touch]]


*[[Media:XO-4_CB.pdf |IEC 60950-1 cert. for XO-1.75/XO-4/XO-4 Touch]]
*[[Media:XO-4_CB.pdf |IEC 60950-1 cert. for XO-1.75/XO-4/XO-4 Touch]]
Line 15: Line 16:
*[[Media:XO-4_CPSIA.pdf|USA CPSIA Compliance]] (Lead and Phthalates)
*[[Media:XO-4_CPSIA.pdf|USA CPSIA Compliance]] (Lead and Phthalates)


=EMC Test Reports=
=CE/EU Certifications=
The testing strategy is to ensure compliance with both EU and FCC RF and EMI regulations. Most other countries in the world either accept the results of this testing for certification or have similar tests which can be passed if the EU/FCC standards are met.

==CE/EU Certifications==


*[[Media:XO-4_CE_EMC.pdf|CE EMC Report]] (802.11b/g WLAN)
*[[Media:XO-4_CE_EMC.pdf|CE EMC Report]] (802.11b/g WLAN)
Line 25: Line 29:
*[[Media:XO-4_CE_Photos.pdf|CE EMC Laptops Photos]]
*[[Media:XO-4_CE_Photos.pdf|CE EMC Laptops Photos]]


=FCC/US Certifications=
==FCC/US Certifications==


*[[Media:XO-4_FCC_RF_Safety_Insert.pdf|RF Safety Insert]]
*[[Media:XO-4_FCC_RF_Safety_Insert.pdf|RF Safety Insert]]
Line 35: Line 39:
*Various ID grants: [[Media:XO-4_FCC_DTS.pdf|DTS]], [[Media:XO-4_FCC_DSS.pdf|DSS]], [[Media:XO-4_FCC_NII.pdf|NII]]
*Various ID grants: [[Media:XO-4_FCC_DTS.pdf|DTS]], [[Media:XO-4_FCC_DSS.pdf|DSS]], [[Media:XO-4_FCC_NII.pdf|NII]]


=Australian Certifications=
=International Certifications=
In addition to the US and the EU certifications listed above, certification for the following countries is already on file for the [[XO-4]].

==Australian Certifications==


*[[Media:XO-4_ACMA_DOC.pdf|ACMA Declaration of Conformity]]
*[[Media:XO-4_ACMA_DOC.pdf|ACMA Declaration of Conformity]]
Line 41: Line 48:
*[[Media:XO-4_CE_SAR.pdf|CE/ACMA SAR Testing]]
*[[Media:XO-4_CE_SAR.pdf|CE/ACMA SAR Testing]]
*[[Media:XO-4_CTick_Q_EMC.pdf|C-Tick EMC Report]] (Quanta testing)
*[[Media:XO-4_CTick_Q_EMC.pdf|C-Tick EMC Report]] (Quanta testing)

=Robustness=
A hardware testing specification is used to certify that the laptop has acceptable robustness. The manufacturer, Quanta, certifies that samples of the laptop pass this specification. The XO-4 Touch introduced a new set of testing specifications, based on the one used for [[XO-1]], [[XO-1.5]], and [[XO-1.75]].
*[[Media:XO-4_Test_Spec.pdf|Hardware Test Specification (PDF)]] ([[Media:XO-4_Test_Spec.xls|xls]])

==Battery Test Data==
*[[Media:shortcircuit.xls |short circuit]]
*[[Media:stovetest.xls |stove test (150C)]]
*[[Media:crushtest.xls |crush test]]
*[[Media:nailtest.xls |nail test (drive a nail through the battery)]]
*[[Media:overcharge.xls |overcharging test]]

==AC Adapter==
*[[Media:XO-1.5_Adapter_Spec.pdf|Adapter Specification]]
*90v(-10%) ~ 240v(+25%), 35-60Hz, AC input
*Safety: IEC 60950-1, EN 60950-1 & CSA/UL 60950-1 qualified
*Extra Transient and Burst Immunity: IEC 61000-4-4 passed
*Extra Surge Immunity: IEC 61000-4-5 passed

=Quality Control=
The Quanta factory meets [http://en.wikipedia.org/wiki/ISO_9000 ISO 9001] standards: [[Media:ISO9001.pdf |QSMC F6 ISO 9001 Certificate]]


[[Category:Hardware]]
[[Category:Hardware]]

Latest revision as of 03:42, 13 September 2013

  This page is monitored by the OLPC team.

This page contains safety and RF emission test reports and certifications for the XO-4 Laptop.

Safety

The XO-4 Laptop comes in four variants: the XO-4, the XO-4 HS (a non-membrane keyboard), the XO-4 Touch, and the XO-4 HS Touch. These have the following Safety certifications:

EMC Test Reports

The testing strategy is to ensure compliance with both EU and FCC RF and EMI regulations. Most other countries in the world either accept the results of this testing for certification or have similar tests which can be passed if the EU/FCC standards are met.

CE/EU Certifications

FCC/US Certifications

International Certifications

In addition to the US and the EU certifications listed above, certification for the following countries is already on file for the XO-4.

Australian Certifications

Robustness

A hardware testing specification is used to certify that the laptop has acceptable robustness. The manufacturer, Quanta, certifies that samples of the laptop pass this specification. The XO-4 Touch introduced a new set of testing specifications, based on the one used for XO-1, XO-1.5, and XO-1.75.

Battery Test Data

AC Adapter

  • Adapter Specification
  • 90v(-10%) ~ 240v(+25%), 35-60Hz, AC input
  • Safety: IEC 60950-1, EN 60950-1 & CSA/UL 60950-1 qualified
  • Extra Transient and Burst Immunity: IEC 61000-4-4 passed
  • Extra Surge Immunity: IEC 61000-4-5 passed

Quality Control