XO B2: Difference between revisions

From OLPC
Jump to navigation Jump to search
m (B2 moved to XO B2: Namespace control)
No edit summary
Line 1: Line 1:
Beta test model BTest-2, also known as B2.
XO Laptop Beta test model BTest-2, also known as B2.


Approximately 2500 systems were built by Quanta and distributed. These are fully functional machines with CaFE ASICs, and reflect some, but not all of the learning and improvements from testing of BTest-1. Much more information about the BTest-2 systems can be found in the [[BTest-2 Release Notes]].
See [[BTest-2_Release_Notes]] and [[Hardware_specification#Beta_Test_2_Systems_.28BTest-2.2C_or_B2.29|Beta Test 2 Systems]]

*two variants, B2-1 and B2-2,


== Identification ==
== Identification ==


BTest-2 laptops are almost identical visually with [[XO_B1|BTest-1 laptops]]. An easy way to tell the difference between [[XO_B1|BTest-1]] and BTest-2 is that BTest-1 keyboards have white lettering, and BTest-2 has black lettering.
*labels under battery include "B2-7" and "B2 - TEST SAMPLE"

There are two flavors of B2:
* Beta Test '''2-1''' (B2-1) systems, which only have 128 MB of memory, have a label under the battery that says '''B2-TEST-SAMPLE''' and a label that says '''B2-#''', where # is one to 16.
* Beta Test '''2-2''' (B2-2) systems, which have 256MB of memory, have a label under the battery that says '''B2-7-ext'''.

== Software Support ==

* B2-1 laptops have insufficient RAM for builds after 406. (The automatic firmware upgrade will
cause problems on later builds!)
*firmware tested up to Q2C27 only, do not upgrade beyond this version of firmware unless specific support for model is mentioned, per [http://lists.laptop.org/pipermail/devel/2007-September/006767.html olpc-devel mail 2007-September/006767].


== Restrictions ==
== Restrictions ==
Line 14: Line 22:
** no wake on keyboard or touchpad (#895),
** no wake on keyboard or touchpad (#895),
** DCON will glitch on wake (#947),
** DCON will glitch on wake (#947),
*insufficient RAM for builds after 406,
*firmware tested up to Q2C27 only, do not upgrade beyond this version of firmware unless specific support for model is mentioned, per http://lists.laptop.org/pipermail/devel/2007-September/006767.html
*video problems due to hardware design flaw, new camera activity will not work, older camera activity will.
*video problems due to hardware design flaw, new camera activity will not work, older camera activity will.
*[[No_serial_number|no serial number]]
*[[No_serial_number|no serial number]]
Line 21: Line 27:
== Followed by ==
== Followed by ==


* [[B3]]
* [[XO_B3|B3]]


== Preceeded by ==
== Preceeded by ==


* [[B1]]
* [[XO_B1|B1]]


[[Category:Hardware]]
[[Category:Hardware]]
[[Category:XO]]

Revision as of 05:06, 6 January 2009

XO Laptop Beta test model BTest-2, also known as B2.

Approximately 2500 systems were built by Quanta and distributed. These are fully functional machines with CaFE ASICs, and reflect some, but not all of the learning and improvements from testing of BTest-1. Much more information about the BTest-2 systems can be found in the BTest-2 Release Notes.

Identification

BTest-2 laptops are almost identical visually with BTest-1 laptops. An easy way to tell the difference between BTest-1 and BTest-2 is that BTest-1 keyboards have white lettering, and BTest-2 has black lettering.

There are two flavors of B2:

  • Beta Test 2-1 (B2-1) systems, which only have 128 MB of memory, have a label under the battery that says B2-TEST-SAMPLE and a label that says B2-#, where # is one to 16.
  • Beta Test 2-2 (B2-2) systems, which have 256MB of memory, have a label under the battery that says B2-7-ext.

Software Support

  • B2-1 laptops have insufficient RAM for builds after 406. (The automatic firmware upgrade will

cause problems on later builds!)

Restrictions

  • electrical system defects, while running Q2D05 firmware, see #1835, #1752, #4476, #4479, #895, #947,
    • no wake on keyboard or touchpad (#895),
    • DCON will glitch on wake (#947),
  • video problems due to hardware design flaw, new camera activity will not work, older camera activity will.
  • no serial number

Followed by