XO Troubleshooting USB: Difference between revisions

From OLPC
Jump to navigation Jump to search
mNo edit summary
No edit summary
Line 17: Line 17:
==Motherboard signal integrity==
==Motherboard signal integrity==
The [[XO_Self_Test|hardware self-test]] provided by [[Open Firmware]] contain a section where test signals for the USB ports are output, allowing signal integrity (eye diagrams) of the traces between the Southbridge and the connectors to be made using an oscilloscope.
The [[XO_Self_Test|hardware self-test]] provided by [[Open Firmware]] contain a section where test signals for the USB ports are output, allowing signal integrity (eye diagrams) of the traces between the Southbridge and the connectors to be made using an oscilloscope.

==A specific USB drive won't mount==
Some models of USB drives may be more compatible with the XO laptop than others. For example, a number of USB drives ship with [http://en.wikipedia.org/wiki/U3 U3] software pre-installed. U3 is software for a Windows PC and it's presence on a USB drive prevents successful mounting of the drive on the XO laptop. Further, presence of the U3 software on a drive may cause the XO to incompletely mount the drive, in such a way that even if you can remove the U3 software, the remanents of the incomplete mount will still prevent a successful mount. (Re-formatting the USB drive from a Windows computer should remove the U3 software and any remnants of an prior incomplete mount.)


[[Category: Repair]]
[[Category: Repair]]

Revision as of 15:56, 26 February 2009

  This page is monitored by the OLPC team.
  english | español HowTo [ID# 196523]  +/-  

This is the portion of the XO Troubleshooting Guide for diagnosing problems with the USB interfaces of an XO laptop.

One of the USB ports doesn't work

This is typically due to broken connector or solder joint at the affected connector.

All of the USB ports receive power from a common switch, so if a problem with power is localized to one port it is likely due to a broken connector or solder joint at the connector.

The USB signals run directly from the connectors to the CS5336 Southbridge. If there is a signal integrity problem, and it is not at the connector, the motherboard must be replaced.

There is no repair for this motherboard

None of the USB ports work

If none of the USB ports on a laptop work, even after re-installing the software, then the motherboard needs to be replaced.

Measure the +5V supply at the USB connector (or across C509 or C551). If it is not present, the USB power switch and current limiter, U56, may be broken. It may be bypassed by a 0 ohm resistor at R466 for testing purposes. If the audio (speakers) is also non-functional, that verifies that the problem is the +5V supply on the motherboard.

Motherboard signal integrity

The hardware self-test provided by Open Firmware contain a section where test signals for the USB ports are output, allowing signal integrity (eye diagrams) of the traces between the Southbridge and the connectors to be made using an oscilloscope.

A specific USB drive won't mount

Some models of USB drives may be more compatible with the XO laptop than others. For example, a number of USB drives ship with U3 software pre-installed. U3 is software for a Windows PC and it's presence on a USB drive prevents successful mounting of the drive on the XO laptop. Further, presence of the U3 software on a drive may cause the XO to incompletely mount the drive, in such a way that even if you can remove the U3 software, the remanents of the incomplete mount will still prevent a successful mount. (Re-formatting the USB drive from a Windows computer should remove the U3 software and any remnants of an prior incomplete mount.)