XO 1.5 EC dev changelog: Difference between revisions
Jump to navigation
Jump to search
Line 13: | Line 13: | ||
* Refactor 1-w states to break up some of the larger complex states. |
* Refactor 1-w states to break up some of the larger complex states. |
||
* 1 wire state machines are now run every 100ms. |
* 1 wire state machines are now run every 100ms. |
||
Known Issues: |
|||
* Battery debugging output was left enabled if you connect up a battery you will get a dump of various variables every second. |
|||
---- |
---- |
Revision as of 14:27, 25 June 2009
1.5 EC development change log
Ver: 1.9.2
Fixes:
- reorder the scancode generation table to match the new ordering from the rewritten GetMatrixKeys.
- Modify the polarity of some signals so they don't create leakage in S5
- Reduce the VR_ON to RSMRST# delay to approx 20ms as requested by Beckham Chen @ quanta.
- Fix no low voltage host shut off bug.
- Battery charge taper current tweak 100mA -> 150mA.
Features:
- Refactor 1-w states to break up some of the larger complex states.
- 1 wire state machines are now run every 100ms.
Known Issues: