XO4 B1 C1 Changes: Difference between revisions
(Created page with 'These are the changes planned for the XO-4 C1 prototype, from the B1 prototypes. The list of changes made to the B1 prototypes as part of testing is the […') |
No edit summary |
||
Line 6: | Line 6: | ||
=B1 Layout Fixes= |
=B1 Layout Fixes= |
||
==Display Screws== |
|||
The layout has to change to make room for [[#Display_Mounting|display mounting screws intruding into the motherboard area]]. |
|||
==Correct IR PCB FFC Connector== |
==Correct IR PCB FFC Connector== |
||
Line 11: | Line 14: | ||
* Ensure that CN5 has the correct layout. |
* Ensure that CN5 has the correct layout. |
||
=B1 Mechanical Changes= |
|||
==Display Mounting== |
|||
The Display mounting screws in C1 will be the same as current XO-1.75 production. The B1 prototypes used a shorter screw to avoid damaging the motherboard. The motherboard will have to be modified to allow for an intrusive display screw boss. |
|||
==Speaker Mounting== |
|||
This has to improve. It failed in 20% of the units in shipping air freight from QSMC to Cambridge! |
|||
==Touchscreen FFC Connector== |
|||
How is the cable connected to avoid stressing the connector on the IR PCB ? |
|||
=Planned Feature Changes= |
=Planned Feature Changes= |
Revision as of 02:42, 3 October 2012
These are the changes planned for the XO-4 C1 prototype, from the B1 prototypes. The list of changes made to the B1 prototypes as part of testing is the XO-4 B1 ECO list.
B1 Electrical Fixes
These changes fix problems in the B1 prototypes:
B1 Layout Fixes
Display Screws
The layout has to change to make room for display mounting screws intruding into the motherboard area.
Correct IR PCB FFC Connector
The connector for the FFC cable to the IR PCB assembly had its pinout reversed accidentally in B1. This was fixed in B1 units by using a reversed FFC with an ugly bend.
- Ensure that CN5 has the correct layout.
B1 Mechanical Changes
Display Mounting
The Display mounting screws in C1 will be the same as current XO-1.75 production. The B1 prototypes used a shorter screw to avoid damaging the motherboard. The motherboard will have to be modified to allow for an intrusive display screw boss.
Speaker Mounting
This has to improve. It failed in 20% of the units in shipping air freight from QSMC to Cambridge!
Touchscreen FFC Connector
How is the cable connected to avoid stressing the connector on the IR PCB ?