Typical capacity: 3050 mAh ''Only 80% of this capacity is usable'' <br>
Typical capacity: 3050 mAh <br>
Minimum capacity: 3000 mAh <br>
Minimum capacity: 3000 mAh <br>
''Only 80% of this capacity is usable'' <br>
Operating Voltage Rage: 7.5V to 5V at 0.2C discharge current <br>
Operating Voltage Rage: 7.5V to 5V at 0.2C discharge current <br>
Operating Temp Charge: 0 ~ +45°C <br>
Operating Temp Charge: 0 ~ +45°C <br>

Revision as of 15:50, 22 August 2007

Types of Batteries

OLPC is using two battery chemistry's from 2 vendors: NiMH, and LiFePo4 batteries. The LiFePo4 batteries allow charging at higher temperatures. The NiMH batteries cannot be charged above about 45 degrees C.

Our batteries vendors are Goldpeak and BYD.

GoldPeak provides both NiMH and LiFePo4 packs.
BYD provides only LiFePo4 packs.

Each chemistry and manufacturer have slightly different specifications.

GoldPeak NiMH

Typical capacity: 3050 mAh
Minimum capacity: 3000 mAh
Only 80% of this capacity is usable
Operating Voltage Rage: 7.5V to 5V at 0.2C discharge current
Operating Temp Charge: 0 ~ +45°C
Operating Temp Discharge: -20 ~ +50°C
Standard charge rate: CC-CV .1C [Special Charging instructions]

GoldPeak LiFePo4

Typical capacity: 2900 mAh
Minimum capacity: 2800 mAh
Operating Voltage Rage: 7.3V to 4V at 0.2C discharge current
Operating Temp Charge: 0 ~ +60°C
Operating Temp Discharge: -20 ~ +70°C
Standard charge rate: CC-CV .8C up to 7.3V
Max charge rate:1.5C(4200 mA)

BYD LiFePo4

Typical capacity: 3150 mAh
Minimum capacity: 3100 mAh
Operating Voltage Rage: 7.5V to 5V at 0.2C discharge current
Operating Temp Charge: -10 ~ +50°C
Operating Temp Discharge: -20 ~ +55°C
Max charge rate:1C(3150 mA)

Lifetime requirements for all batteries

Ambient Temperature:25°C
Number of Cycles:2000
Remaining Capacity after 2000 cycles:50%