Ver: 7 0.3.11

  • Allow battery debugging to be enabled via serial port
  • Fix incorrect battery critical LED state
  • Change W to mW in battery debug output to make the scale clearer
  • Add debounce for the thermal alarm signal and enable a new LED state when triggered. (Alternating power LED and red battery LED)
  • Blink code for high battery current prior to stop mode (Alternating Green/Yellow)
  • Blink code for exiting stop mode while power is off (Alternating Green/Red)

Ver: 7 0.3.10

  • Fix NiMH pre-maturely marked full problem

Ver: 7 0.3.09

  • Fix logic bug in ext power detect after runin discharge. Machines turning off runin discharge could fail to sense external power.
  • Print ACR value and SOC when going into stop mode
  • Refactor critical and low flag handling to fix corner cases. There were several corner cases where you could get the previous code to display the wrong LED state.
  • Add support for GP LiFePO4 batteries. There are few around the Twine offices.
  • Turn off battery state debugs in LiFePO4 code
  • kbdwatch: wait longer after seeing SOC_SLEEP to release flow-control. Fixes a lockup on 1Ghz MMP3.

Ver: 7 0.3.08

  • Make sure full flag is clear when SOC is < 95%
  • Up bad ACR read difference threshold to 20 counts
  • Come out of stop mode once in a while, to do housekeeping
  • adjust the timings for the EC_IRQ assertions

Ver: 7 0.3.07

  • Check battery EEPROM bank 0 values and fix them if wrong
  • Detect bad ACR register reads from the battery due to ESD and discard them
  • Generate 2 wake up interrupts to the SoC on resume. One to make it wake up and then a 2nd to actually make it start executing. Works around resume problems.

Ver: 7 0.3.06

  • Change battery over temperature indicator to be a pulse of dark (both LEDs off) rather than a pulse of red. Red is now exclusively for errors.
  • Fix typo in IO map causing LV_SET code to mess with EC_IRQ.