BTest-4 Release Notes

From OLPC
Revision as of 13:36, 2 August 2007 by Jg (talk | contribs) (Initial BTest-4 hardware release notes.)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to: navigation, search
  This page is monitored by the OLPC team.


The Meaning of BTest-4

Please set a "watch" (the little tab on top of the wiki page) on this page to be notified when the release notes change.

BTest-4 hardware is very close to production hardware. BTest-4 can easily be distinguished from BTest-3 and before because the plastic around the handle has been textured (and the bezel around the screen is gray, helping use in bright sunlight). There will be a small CTest build in mid-August to verify the production "recipe", but these will not see wide distribution.

BTest-3 was a small build, with the new LX processor built for testing, and not distributed in quantity. For all practical purposes, BTest-3 is identical to BTest-4.

There are typically one or two builds of systems internally before an external beta test; the BTest-2 build was earlier in the development cycle than systems are usually made available, and were correspondingly rougher.

Hardware Specification

BTest-4 systems all have 1 gigabyte of flash, and 256M of RAM. It uses the substantially faster Geode LX processor, with a larger cache and better graphics processor. Interpreted languages such as Python in particular benefit greatly from the larger cache.

We are also using an alternate battery chemistry in addition to NiMH; a lithium based battery chemistry (LiFePo) has become available that has few of the safety or environmental problems of Lithium Ion, is less costly than NiMH (Nickel prices have gone through the roof in the last 10 months), and can charge at much higher temperatures, important for use in some parts of the world which can be so hot as to exceed the temperature at which NiMH can be charged. These batteries can be identified by large labels "Battery Sample" on the battery packs, and are significantly lighter than NiMH. LiFePo batteries have somewhat higher capacity than NiMH.

The hardware specification is elsewhere in the wiki.

Software Release Notes

There is a separate page for Software Release Notes. For an introduction to the machine's software, see the B1 Demo Notes page.

Library Release Notes

OLPC has started a Library of material. The Library Release Notes has release note information about the early content available.

Hardware Release Notes

The BTest-4 hardware has been extensively tested to ensure that it works correctly in all modes for suspend resume and power management. A very few changes (resistor values on the LCD chain) and similar items will be changed for CTest and production that will slightly reduce power consumption.

A number of software issues remain open. Note that the software does not yet have suspend on idle implemented. There are quite a few places where we can do better on power consumption

Our master list of hardware and mechanical issues and status can be found in the trac system we use. Please check this list before entering new issues: but please do enter issues you discover. The items below are the most significant from the list.

Power management
Suspend and resume are mostly functional. A number bugs still affect both power consumption when suspended, and are actively being worked. The most irritating right now is the wireless firmware may not recover on resume, and a window system problem where the screen won't come back on after resume. Note that only BTest-3/4 systems will resume on keyboard or touchpad touch.
Wakeup event is repeated continuously
Ebook mode (aggressively suspending the system with the screen on) is latent in the software already (can be turned on by touching a file), but awaits resolution of this bug between the embedded controller and Linux causing continuous scrolling.

Fixed Since BTest-1

These problems have all been resolved in BTest-4.

The keyboard may have problems due to a short cable
The most irritating problem on BTest-2 is the fact that the keyboard may stop working properly, due to a cable 1mm too short and slightly too much insulation. Flexing the base of the system may pull the cable out of its connector. The field repair of reseating the connector (which requires disassembling the base assembly) is not all that difficult, but annoying.
LiFe batteries incorrectly flash red light
LiFe batteries are lighter and have "battery sample" on the back; if they flash the red "battery low" LED, removing and reinserting the battery will get the indicator back to correctness. EC code has been fixed.
The battery charging algorithms have problems
The old EC code shipped with some units had a bug which prevented startup with low battery and another bug which prevented charging with a low battery, and also high power usage by the EC, which would drain a battery if left unplugged in a matter of a day or two. Updating to current firmware should fix most battery charging problems; please report any further difficulties. Please read this bug report for more information. BTest-2 and later should also be able to "resurrect" batteries that are so discharged that they cannot even be sensed when put into a system by a new trickle charger circuit. Unfortunately, there are a few batteries which cannot be recovered, due to flash memory in the battery being set to the wrong value, so the battery cannot talk to the laptop.
Inconsistent battery charge state indications
Fixed Q2B81 and later firmware. The EC can't report proper charging or capacity information and is overly conservative on the amount of power remaining, as the hardware chosen for the battery pack to report capacity is incorrect; this is fixed in the BTest-3 build.
Keyboard keys occasionally stop working, and sometimes the machine does not reboot.
(ESD problem with the embedded controller.) This has not been seen on BTest-2 hardware. One of the most irritating and noticeable problems using BTest-1 systems is a static discharge problem that can lockup pins or entirely crash the embedded controller, causing some or all of the keyboard keys or touch pad to stop functioning (requiring removing the battery for a period to allow the EC to reset fully). We believe this has been fixed in BTest-2. We will therefore be very interested if anyone sees this problem in BTest-2.
Internal Microphone
The internal microphone is still mispositioned in BTest-2 (too close to the speaker), and build 239 does not have the codec properly configured to avoid feedback. One of the second source microphones is particularly bad. The BTest-3 hardware has the microphone on the other side of the screen.
fn is last in 'salute'
Touchpads are too "noisy"
This is being mitigated with the addition of a Mylar sheet on top of each touchpad. The Mylar sheets improve touchpad performance for B-Test 1 machiness too. You can also recalibrate the touchpad, by touching all four corner keys at the same time (aka four finger salute), and should expect to need to when you change the laptop to and from power. The Mylar sheet looks like a plastic sheet -- you should not remove it, else touchpad accuracy will decrease. BTest-3 touchpads should be auto-recalibrating and have the sheet integrated.
SD high-speed not working yet
We now do support high-speed SD, but are not seeing very high transfer rates when in high-speed mode yet. Fixed in build 303.
Hardware performance is not what it will be
Fixed in the Q2B81 and later firmware. The B-Test systems run 33% slower when USB networking is in use -- the internal wireless device is connected over USB, so triggers this problem.
The resistive sensor does not work
(for use with a stylus for writing), due to a design flaw: This is fixed on BTest-2 systems.
The arrow keys ("game keys") cannot be distinguished from the arrow keys on the keyboard
This is fixed on BTest-2 systems.
The screen is covered by a plastic film by mistake
This was resolved in BTest-2, and a diffuser coating significantly improves the screen quality.
Manufacturing data values are in the wrong order
This is fixed in BTest-2 (and when BTest-1 systems' firmware is first upgraded).

Design Release Notes

Note that the design is frozen for FRS.

The hinge on BTest-4 allows for the screen to be tilted further back.

The BTest-2 systems do not have textured plastic: BTest-4 has a sample of the texturing on the battery cover plastic.

Other design issues are also under investigation
Note that design is always an over constrained problem: it is often not possible to get every thing you would like in a design, though you can usually get most or all of what you value most.

Problems fixed in BTest-3/4