This page describes the production test support provided with the touchscreen in XO-4.

Test routines are provided in Open Firmware for testing the various components of the touchscreen system, at various stages of manufacture.

IR PCB SMT

This test is done to bare IR PCB boards, without a light guide. The code runs on XO-4 A2 or later motherboards.

The idea is to check for opens and shorts of the IR diodes and detectors, as well as proper mounting of the ASIC and connector on the IR PCB.

There should be no operator interaction with the IR PCB. They should simply be able to drop a board into the test fixture, press a button on the keyboard, and the screen says pass or fail with an appropriate background (red/green).

After testing is complete, the MSP430 should probably be placed into reset to allow for cable disconnect. It should be rebooted for each test.

select /touchscreen
0 to faults  test-os
faults  if  green-screen  else  red-screen  then
touch-rst-gpio# gpio-clr
key drop

IR PCB ASSY

This test is done to IR PCB assemblies, including a light guide and bezel. The code runs on XO-4 A2 or later motherboards in a production line situation, using a test fixture to connect to the bezel assembly.

The idea is to check for proper assembly of the lightguide and IR PCB, as well as proper lightguide and IR PCB operation.

They should simply be able to drop a bezel assembly into the test fixture, and press a button on the keyboard. They then need to pass a finger or stylus along two adjacent inside edges of the bezel to complete the test. Upon completion, the screen says pass or fail with an appropriate background (red/green). There should be an automatic abort of the test (w. fail) if the appropriate motion isn't detected within thirty seconds.

After testing is complete, the MSP430 should probably be placed into reset to allow for cable disconnect. It should be rebooted for each test.

  • can be done now with revision A IR PCBA if the finger or stylus is omitted:
select /touchscreen
0 to faults  test-fss
faults  if  green-screen  else  red-screen  then
touch-rst-gpio# gpio-clr
key drop
  • waiting on revision B IR PCBA for implementation:
select /touchscreen
0 to faults  test-edges
faults  if  green-screen  else  red-screen  then
touch-rst-gpio# gpio-clr
key drop

MB SMT

This test is done to each bare laptop motherboards as part of SMT testing (TS code SMT). The code runs on XO-4 A2 or later motherboards.

The idea is to check for proper functioning of the touchscreen microcontroller and connector to the IR PCB.

There should be no operator interaction with the "known good" IR PCB. The operator should be able to drop a motherboard into the test fixture and power it on --starting the automatic test menu. When run the touchscreen test shall attempt to install firmware into the microcontroller, then attempt to communicate with the "known good" IR PCB. The test result should be indicated visually and the automated test stopped on failure.

MB ASSY

This test is done to each assembled laptop as part of assembly testing (TS code ASSY). The code runs on XO-4 A2 or later motherboards.

The idea is to check for proper functioning of the touchscreen microcontroller, IR PCB/lightguide assembly, and the connection between the two.

The operator will power the laptop on --starting the automatic test menu. When run, the touchscreen test shall establish communications with the microcontroller. Then it should wait for the operator to run their finger/stylus along two adjacent edges of the light guide. The test result should be indicated visually and the automated test stopped on failure. If no operator input is detected in a fixed amount of time (thirty seconds), the test should be stopped indicating failure.

Lightguide Tooling

Field

test /touchscreen