Talk:Suspend and resume

From OLPC
Revision as of 07:33, 18 January 2008 by Co149 (talk | contribs) (what about those weird units, anyway...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search

Testing Suspensions

The "weird" units of accum_current seem to be joules*10 (or kilojoules/100; that would be consistent with the temperature units degreesC/100). Anyway, I ran /usr/bin/olpc-logbat into a spreadsheet and compared the accum_current values with a prediction based on accumulating current_avg * voltage_avg. they were pretty close, a small error that grows linearly over time. this is to be expected, i guess, since the current and voltage are 10-second averages and not the actual instantaneous numbers that accumulate into accum_current. Co149 02:33, 18 January 2008 (EST)