Talk:Suspend and resume

From OLPC
Revision as of 07:33, 18 January 2008 by Co149 (talk | contribs) (what about those weird units, anyway...)
(diff) ← Older revision | Latest revision (diff) | Newer revision → (diff)
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Testing Suspensions

The "weird" units of accum_current seem to be joules*10 (or kilojoules/100; that would be consistent with the temperature units degreesC/100). Anyway, I ran /usr/bin/olpc-logbat into a spreadsheet and compared the accum_current values with a prediction based on accumulating current_avg * voltage_avg. they were pretty close, a small error that grows linearly over time. this is to be expected, i guess, since the current and voltage are 10-second averages and not the actual instantaneous numbers that accumulate into accum_current. Co149 02:33, 18 January 2008 (EST)